TD Silent Series – TD-800/200SILT-4PL
Performance Curve - TD-800/200SILT-4PL
Description
The TD Silent Series of low-profile mixed-flow in-line fans incorporates a break-through in noise reduction resulting in units that operate very quietly. The low noise levels are achieved through the technically advanced design of the internal construction, which does not impede on the air flow performance of the fan.
There are 6 models in the series, ranging from 100 to 315mm diameter spigot sizes.
Features High performance mixed-flow impeller.
Low noise operation.
Vibration absorbing elements are integrated into the advanced body design.
360° rotating junction box makes connection of power cable easier (applicable for 100, 125, 150 and 200mm sizes only).
Integral mounting foot makes installation more simple.
1 to 30 minute run-on timer available on 100 to 200mm models.
Includes plug and lead for easy installation.
Convenient 2-speed motor, factory set to high speed (single speed on models with run-on timer).
Fan body can be easily removed without disturbing connected ductwork.
Construction
Casings manufactured from reinforced, injection moulded, polypropylene plastic.
Impellers are made of injection moulded plastic and are a mixed-flow design.
Motors
Type:
Standard models - 2-speed, squirrel cage induction motor.
Models with run-on timer - Single-speed, squirrel cage induction motor.
Electricity supply - 230V, single-phase, 50Hz.
Bearings - sealed for life, ball.
Speed-controllable using VA type speed controllers in high speed only. Not applicable to models with run-on timer.
Class B Insulation, IP44.
Internal Thermal Protection
Manual-reset thermal overload protection device in
accordance with mandatory requirements for in-line fans, AS/NZS60335-2-80:2004
Testing
Air flow tests to ISO5801: Part1, 1997 and AMCA 210-99
Noise to ISO 13347-3 2004
Suggested Specification
The In-line fans shall be of the TD Silent Series as supplied by Fantech Pty. Ltd.
Impellers shall be of mixed-flow design and driven by single-phase motors with thermal overload protection.
Fans shall include vibration absorbing elements and sound absorbing material.
They shall also include an integral mounting foot and a power lead with plug.
The fan body can be removed without disturbing connecting ductwork.
All fans shall be fully tested to ISO5801: Part 1, 1997 or AMCA
210-99 for air flow and ISO13347-3, 2004 for noise.Technical Data - TD-800/200SILT-4PL
Speed [rps] | Avg. dBA @ 3m | kWatts (Input) | Amps | Max.°C | Approx. Weight [kg] |
---|
46 | 42 | 0.102 | 0.45 | 60 | 8.7 |
Sound Data
Type | 63 | 125 | 250 | 500 | 1K | 2K | 4K | 8K |
---|
Inlet | 51 | 54 | 55 | 58 | 58 | 57 | 53 | 47 |
Outlet | 68 | 61 | 58 | 61 | 59 | 57 | 54 | 48 |
Dimensions
A | B | C | D | E | F | G | H |
---|
145 | 129 | 296 | 296 | 340 | 164 | 568 | 198 |
*All dimensions in mm, unless otherwise stated
Ancillaries